    "identifier": {
        "identifier": "10.25039/CIE.DS.van56dfj",
        "identifierType": "DOI"
    },
    "creators": [
        {
            "name": "International Commission on Illumination (CIE)",
            "nameType": "Organizational"
        }
    ],
    "titles": [
        {
            "title": "CIE reference spectrum L41"
        }
    ],
    "publisher": "International Commission on Illumination (CIE), Vienna, AT",
    "publicationYear": "2023",
    "subjects": [],
    "language": "en",
    "alternateIdentifiers": [
        {
            "alternateIdentifier": "CIE_RefSpectrum_L41.csv",
            "alternateIdentifierType": "fileName"
        }
    ],
    "relatedItems": [
        {
            "relatedItemIdentifier": "10.25039/TR.251.2023",
            "relatedItemIdentifierType": "DOI",
            "relationType": "IsPartOf",
            "relatedItemType": "Report",
            "titles": [
                "CIE 251:2023 LED Reference Spectrum for Photometer Calibration"
            ]
        }
    ],
    "formats": [
        "text/csv"
    ],
    "types": {
        "resourceType": "dataTable",
        "resourceTypeGeneral": "Dataset"
    },
    "descriptions": [
        {
            "description": "Relative spectral power distribution of the CIE reference spectrum L41, wavelength range: 360 nm to 830 nm, wavelength increment: 1 nm, original source: CIE 251:2023 Table 1",
            "descriptionType": "Abstract"
        }
    ],
    "rightsList": [
        {
            "rights": "Creative Commons Attribution-ShareAlike 4.0 International",
            "rightsURI": "https://creativecommons.org/licenses/by-sa/4.0/",
            "rightsIdentifier": "CC BY-SA 4.0"
        }
    ],
    "checksums": [
        {
            "hashMethod": "md5",
            "checksum": "01dba8b4ebdbd2a3ebb9fa6cc8719939"
        },
        {
            "hashMethod": "sha256",
            "checksum": "23e07c6b8a2f5273f9e3abb3c64a374f3456eee0a70dd447fdb14c617f55224e"
        }
    ],
    "datatableInfo": {
        "validations": [
            {
                "validationType": "sumOfColumns",
                "validationValue": "[280245,3162.483031]"
            },
            {
                "validationType": "sampleRow",
                "validationParameter": "13",
                "validationValue": "372,0.000525"
            }
        ],
        "interpolationMethod": "linear",
        "extrapolationMethod": "zero",
        "dataQuality": "approximated",
        "columnHeaders": [
            {
                "title": "lambda",
                "unit": "nm",
                "quantity": "wavelength",
                "wavelength_first": 360,
                "wavelength_last": 830,
                "wavelength_step": 1
            },
            {
                "title": "S_L41(lambda)",
                "unit": "dimensionless",
                "quantity": "spectral distribution",
                "wavelength_first": 360,
                "wavelength_last": 830,
                "wavelength_step": 1
            }
        ]
    },
    "schemaName": "CIEmetaDigitalProduct",
    "schemaVersion": 4,
    "schemaURL": "https://doi.org/10.25039/CIE.SC.4taqevcd"
}