    "identifier": {
        "identifier": "10.25039/CIE.DS.mjdd2enu",
        "identifierType": "DOI"
    },
    "creators": [
        {
            "name": "International Commission on Illumination (CIE)",
            "nameType": "Organizational"
        }
    ],
    "titles": [
        {
            "title": "Relative spectral power distributions of CIE illuminant C"
        }
    ],
    "publisher": "International Commission on Illumination (CIE), Vienna, AT",
    "publicationYear": "2018",
    "subjects": [
        {
            "subject": "Colorimetry"
        },
        {
            "subject": "Colour of objects"
        },
        {
            "subject": "Colour vision"
        },
        {
            "subject": "Perception of colour"
        }
    ],
    "language": "en",
    "alternateIdentifiers": [
        {
            "alternateIdentifier": "CIE_illum_C.csv",
            "alternateIdentifierType": "fileName"
        }
    ],
    "relatedItems": [
        {
            "relatedItemIdentifier": "10.25039/tr.015.2018",
            "relatedItemIdentifierType": "DOI",
            "relationType": "IsPartOf",
            "relatedItemType": "Report",
            "titles": [
                "CIE 015:2018 Colorimetry, 4th Edition"
            ]
        }
    ],
    "formats": [
        "text/csv"
    ],
    "types": {
        "resourceType": "dataTable",
        "resourceTypeGeneral": "Dataset"
    },
    "descriptions": [
        {
            "description": "Relative spectral power distributions of CIE illuminant C, wavelength range: 380 nm to 780 nm, wavelength increment: 5 nm, original source: CIE 015:2018 table 5",
            "descriptionType": "Abstract"
        }
    ],
    "rightsList": [
        {
            "rights": "Creative Commons Attribution-ShareAlike 4.0 International",
            "rightsURI": "https://creativecommons.org/licenses/by-sa/4.0/",
            "rightsIdentifier": "CC BY-SA 4.0"
        }
    ],
    "checksums": [
        {
            "hashMethod": "md5",
            "checksum": "bb325f040bab332d91f8d9447aa47b78"
        },
        {
            "hashMethod": "sha256",
            "checksum": "51c53bf065345fc1fb9d50aff40fb0a2ce370bcf35121a3dc4bafc0888602f0b"
        }
    ],
    "datatableInfo": {
        "validations": [
            {
                "validationType": "sumOfColumns",
                "validationValue": "[52380,7327.20]"
            },
            {
                "validationType": "sampleRow",
                "validationParameter": "30",
                "validationValue": "445,123.45"
            }
        ],
        "interpolationMethod": "linear",
        "extrapolationMethod": "zero",
        "dataQuality": "approximated",
        "columnHeaders": [
            {
                "title": "lambda",
                "unit": "nm",
                "quantity": "wavelength",
                "wavelength_first": 300,
                "wavelength_last": 780,
                "wavelength_step": 5
            },
            {
                "title": "CIE illuminant C",
                "unit": "dimensionless",
                "quantity": "spectral distribution",
                "wavelength_first": 300,
                "wavelength_last": 780,
                "wavelength_step": 5
            }
        ]
    },
    "schemaName": "CIEmetaDigitalProduct",
    "schemaVersion": 4,
    "schemaURL": "https://doi.org/10.25039/CIE.SC.4taqevcd"
}